{"id":29661,"date":"2026-09-10T00:29:17","date_gmt":"2026-09-09T21:29:17","guid":{"rendered":"https:\/\/vendor.energy\/vendor-max-endurance-test\/"},"modified":"2026-10-03T14:06:36","modified_gmt":"2026-10-03T11:06:36","slug":"test-rezistenta-vendor-max","status":"publish","type":"page","link":"https:\/\/vendor.energy\/ro\/test-rezistenta-vendor-max\/","title":{"rendered":"Endurance Test"},"content":{"rendered":"\n<section class=\"vendor-hero\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-hero__in\">\n<span class=\"vendor-eyebrow\">\u00cenregistrare intern\u0103 de laborator \u00b7 prototip istoric<\/span>\n<h1>Test de anduran&#539;\u0103<\/h1>\n<p class=\"vendor-lead vendor-hero__lead\">Ce a fost testat, pentru c\u00e2t timp, sub ce sarcin\u0103, cu ce instrumente &#537;i ce s-a \u00eent\u00e2mplat.<\/p>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec vendor-sec--tint\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-copy\">\n<p>Un prototip de laborator VENDOR.Max a finalizat o rulare continu\u0103 de 532 de ore cu o sarcin\u0103 electronic\u0103 reglat\u0103 la aproximativ 4,0 kW &#537;i men&#539;inut\u0103 conectat\u0103 continuu. \u00cen acest interval regimul de func&#539;ionare nu s-a \u00eentrerupt, nu a fost \u00eenregistrat\u0103 nicio defectare hardware, iar portul de utilizator nu a fost deconectat de protec&#539;ia de ie&#537;ire. Rularea a fost oprit\u0103 de operatori. \u00cen continuare urmeaz\u0103 \u00eenregistrarea testului.<\/p>\n<\/div>\n\n<div class=\"vendor-cells vendor-cells--4\">\n<div class=\"vendor-metric\">\n<div class=\"vendor-metric__top\"><span class=\"vendor-label\">Rulare continu\u0103<\/span><\/div>\n<div class=\"vendor-metric__v\">532 <span class=\"vendor-metric__u\">h<\/span><\/div>\n<p>Un interval ne\u00eentrerupt cu configura&#539;ia de sarcin\u0103 men&#539;inut\u0103 conectat\u0103 constant.<\/p>\n<div class=\"vendor-metric__basis\"><span>Surs\u0103: contorul de func&#539;ionare al prototipului<\/span><span>\u00cenregistrare intern\u0103<\/span><\/div>\n<\/div>\n<div class=\"vendor-metric\">\n<div class=\"vendor-metric__top\"><span class=\"vendor-label\">Func&#539;ionare cumulat\u0103<\/span><\/div>\n<div class=\"vendor-metric__v\">1000+ <span class=\"vendor-metric__u\">h<\/span><\/div>\n<p>Func&#539;ionare de laborator &#537;i inginereasc\u0103 \u00een sesiunile \u00eenregistrate.<\/p>\n<div class=\"vendor-metric__basis\"><span>Surs\u0103: contorul de func&#539;ionare al prototipului<\/span><span>\u00cenregistrare intern\u0103<\/span><\/div>\n<\/div>\n<div class=\"vendor-metric\">\n<div class=\"vendor-metric__top\"><span class=\"vendor-label\">Condi&#539;ia de sarcin\u0103 a rul\u0103rii<\/span><\/div>\n<div class=\"vendor-metric__v\">\u22484,0 <span class=\"vendor-metric__u\">kW<\/span><\/div>\n<p>Sarcin\u0103 electronic\u0103 men&#539;inut\u0103 conectat\u0103 pe toat\u0103 durata rul\u0103rii.<\/p>\n<div class=\"vendor-metric__basis\"><span>Reglaj al sarcinii electronice<\/span><span>\u00cenregistrare intern\u0103 de test<\/span><\/div>\n<\/div>\n<div class=\"vendor-metric\">\n<div class=\"vendor-metric__top\"><span class=\"vendor-label\">Port de utilizator<\/span><\/div>\n<div class=\"vendor-metric__v\">Nedeconectat<\/div>\n<p>Protec&#539;ia de ie&#537;ire de 16 A nu a deconectat portul de utilizator.<\/p>\n<div class=\"vendor-metric__basis\"><span>Observat pe intervalul de 532 h<\/span><span>\u00cenregistrare intern\u0103<\/span><\/div>\n<\/div>\n<\/div>\n\n<div class=\"vendor-callout\">\n<p>Aproximativ 4,0 kW descrie condi&#539;ia de sarcin\u0103 electronic\u0103 folosit\u0103 \u00een rularea de anduran&#539;\u0103. Nu este o valoare nominal\u0103 de produs &#537;i nu este publicat\u0103 aici ca valoare a puterii active la portul de utilizator verificat\u0103 independent.<\/p>\n<\/div>\n\n<div class=\"vendor-note\">\n<p>Stare: observa&#539;ie de func&#539;ionare \u00eenregistrat\u0103 de companie. Bilan&#539;ul complet Frame 0 nu a fost \u00eenc\u0103 m\u0103surat de un laborator independent.<\/p>\n<\/div>\n\n<h3>Ce stabile&#537;te aceast\u0103 \u00eenregistrare<\/h3>\n<div class=\"vendor-copy\">\n<p>Aceast\u0103 pagin\u0103 consemneaz\u0103 un rezultat ingineresc, nu o atribuire a sursei de energie. Un prototip fizic a fost pus \u00een func&#539;iune \u00een condi&#539;ii controlate de laborator, a fost solicitat prin mai multe forme independente de \u00eenc\u0103rcare &#537;i observare &#537;i a fost demonstrat \u00een mod repetat \u00een func&#539;ionare. Atribuirea complet\u0103 a sursei de energie la frontiera dispozitivului este o sarcin\u0103 de m\u0103surare separat\u0103.<\/p>\n<p>O explica&#539;ie a observa&#539;iei trebuie s\u0103 dea seama de faptele consemnate \u00eempreun\u0103: absen&#539;a unui bilan&#539; complet Frame 0 nu anuleaz\u0103 observa&#539;ia, iar observa&#539;ia nu identific\u0103 prin sine sursa.<\/p>\n<\/div>\n\n<h3>La ce pot &#537;i la ce nu pot r\u0103spunde aceste m\u0103sur\u0103tori<\/h3>\n<div class=\"vendor-copy\">\n<p>M\u0103sur\u0103torile inginere&#537;ti r\u0103spund la \u00eentrebarea dac\u0103 starea de func&#539;ionare exist\u0103, cum reac&#539;ioneaz\u0103 la reglaje &#537;i la sarcini &#537;i dac\u0103 r\u0103m\u00e2ne stabil\u0103. O atribuire complet\u0103 a sursei de energie cere un alt experiment: contabilizarea sincron\u0103 a tuturor fluxurilor printr-o singur\u0103 frontier\u0103 aleas\u0103, \u00eentr-o singur\u0103 fereastr\u0103 comun\u0103.<\/p>\n<p>Tensiunea &#537;i curentul electric pot fi combinate \u00eentr-un rezultat de putere sau de energie numai dac\u0103 pa&#537;apoartele lor de m\u0103surare sunt compatibile: acela&#537;i port electric definit, sincronizate \u00een timp, pe aceea&#537;i fereastr\u0103 de observare &#537;i cu clase de m\u0103rime compatibile. Celelalte canale se m\u0103soar\u0103 \u00een variabilele proprii naturii lor. Valorile de pe aceast\u0103 pagin\u0103 provin din frontiere diferite, ferestre diferite &#537;i clase diferite.<\/p>\n<\/div>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Ce este fiecare m\u0103rime publicat\u0103 &#537;i ce nu este.<\/caption>\n<thead><tr><th data-num>Valoare<\/th><th>Ce este<\/th><th>Frontier\u0103 &#537;i clas\u0103 temporal\u0103<\/th><th>Ce nu este<\/th><\/tr><\/thead>\n<tbody>\n<tr><td data-num>9 V<\/td><td>Tensiune \u00een timpul evenimentului de pornire<\/td><td>Port de pornire \u00b7 eveniment de aproximativ 10 s<\/td><td>O valoare de energie; intrarea continu\u0103 a rul\u0103rii de 532 de ore<\/td><\/tr>\n<tr><td data-num>24 V, 24 A<\/td><td>M\u0103rimi interne \u00eentr-un punct de m\u0103surare<\/td><td>Plan intern \u00b7 valori medii raportate separat<\/td><td>O putere de intrare Frame 0; o m\u0103surare sincron\u0103 publicat\u0103 a puterii active la acela&#537;i port<\/td><\/tr>\n<tr><td data-num>p\u00e2n\u0103 la 30 kV, p\u00e2n\u0103 la 150 A<\/td><td>Amplitudini ale st\u0103rii rezonante<\/td><td>Plan rezonant intern \u00b7 amplitudine<\/td><td>Putere activ\u0103 livrat\u0103 utilizatorului<\/td><\/tr>\n<tr><td data-num>450 V<\/td><td>Variabil\u0103 de stare a unui nod de acumulare<\/td><td>Condensator dup\u0103 punte \u00b7 nivel de curent continuu<\/td><td>O valoare de putere<\/td><\/tr>\n<tr><td data-num>aproximativ 4,0 kW<\/td><td>Condi&#539;ie de sarcin\u0103 electronic\u0103 a rul\u0103rii de anduran&#539;\u0103<\/td><td>Partea de utilizator \u00b7 lung\u0103 durat\u0103<\/td><td>O valoare nominal\u0103 de produs; o valoare dedus\u0103 din tensiunea de pornire<\/td><\/tr>\n<tr><td data-num>532 h<\/td><td>Interval de func&#539;ionare scurs<\/td><td>Rulare de anduran&#539;\u0103 \u00b7 durat\u0103<\/td><td>O valoare de energie \u00een sine<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"vendor-callout\">\n<p>Pe aceast\u0103 pagin\u0103 nu este publicat niciun numitor pentru un raport energetic. Evenimentul de pornire, m\u0103rimile interne de func&#539;ionare, condi&#539;ia de sarcin\u0103 &#537;i durata apar&#539;in unor frontiere diferite &#537;i unor ferestre de observare diferite, astfel \u00eenc\u00e2t nu formeaz\u0103 num\u0103r\u0103torul &#537;i numitorul unui singur raport. Din valorile publicate nu se poate calcula nici un spor energetic, nici un randament de ansamblu.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Un calcul complet ar necesita o singur\u0103 fereastr\u0103 comun\u0103 de observare la Frame 0: toate fluxurile de intrare &#537;i de ie&#537;ire prin frontier\u0103, inclusiv integrala portului de pornire dac\u0103 pornirea cade \u00een acea fereastr\u0103, \u00eempreun\u0103 cu varia&#539;ia \u00eentregii energii acumulate \u00een interior. Puterea la portul de utilizator, fluxul termic &#537;i fluxul electromagnetic se m\u0103soar\u0103 fiecare \u00een variabilele proprii canalului s\u0103u. Aceast\u0103 \u00eenregistrare nu con&#539;ine o asemenea fereastr\u0103.<\/p>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 2<\/span><h2 id=\"controls\">Ce a fost controlat<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>&#536;ase controale ale programului de testare, prezentate \u00eenaintea oric\u0103rui rezultat. Aceast\u0103 sec&#539;iune raporteaz\u0103 configura&#539;ia.<\/p><\/div>\n<\/div>\n\n<div class=\"vendor-copy\">\n<p>Un prototip de laborator VENDOR.Max istoric. Nu este o unitate de serie &#537;i nu este o configura&#539;ie de prev\u00e2nzare.<\/p>\n<\/div>\n\n<div class=\"vendor-scope\">\n<p>Aceast\u0103 pagin\u0103 descrie prototipul pe care au fost efectuate testele &#537;i pentru care a fost ob&#539;inut\u0103 aceast\u0103 \u00eenregistrare. Ea nu descrie starea actual\u0103 a sistemului. Ce este VENDOR.Max &#537;i unde se afl\u0103 programul \u00een prezent este prezentat \u00een <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/sistemul-vendor\/\">Sistemul VENDOR<\/a>.<\/p>\n<\/div>\n\n<h3>1. Limita sursei de pornire<\/h3>\n<div class=\"vendor-copy\">\n<p>Prototipul a existat \u00een dou\u0103 configura&#539;ii de pornire.<\/p>\n<\/div>\n<div class=\"vendor-callout\">\n<p><strong>Revizia A.<\/strong> O baterie extern\u0103 este conectat\u0103 la portul de pornire numai pentru ini&#539;iere &#537;i este deconectat\u0103 fizic dup\u0103 stabilirea regimului de func&#539;ionare. \u00cen demonstra&#539;ii individuale acest lucru s-a produs dup\u0103 aproximativ 10\u201315 secunde. \u00cen timpul func&#539;ion\u0103rii ulterioare sursa lipse&#537;te fizic din circuit, nu este doar scoas\u0103 de sub tensiune prin logic\u0103.<\/p>\n<p><strong>Revizia B.<\/strong> Pornirea este realizat\u0103 de sistemul intern; bateria r\u0103m\u00e2ne \u00een bucl\u0103 ca tampon bidirec&#539;ional. Rolul s\u0103u este de a acoperi diferen&#539;a temporar\u0103 atunci c\u00e2nd sarcina se modific\u0103 mai repede dec\u00e2t poate sistemul s\u0103 treac\u0103 \u00eentre punctele de func&#539;ionare, nu de a fi sursa puterii de utilizator \u00een regim stabilizat.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Revizia este indicat\u0103 acolo unde este stabilit\u0103 de \u00eenregistrarea testului. Rularea de 532 de ore a fost efectuat\u0103 \u00een configura&#539;ia Revizia A, cu pornire la 9 V timp de aproximativ 10 secunde.<\/p>\n<\/div>\n\n<h3>2. Configura&#539;ia circuitului de sarcin\u0103<\/h3>\n<div class=\"vendor-callout\">\n<p>Sarcina a fost conectat\u0103 la ie&#537;irea de utilizator ca un consumator. Pe partea de sarcin\u0103 nu a existat nicio conexiune separat\u0103 la re&#539;ea, la o baterie, la un generator sau la orice alt\u0103 surs\u0103 de putere independent\u0103 capabil\u0103 s\u0103 returneze continuu energie \u00een prototip.<\/p>\n<p>O sarcin\u0103 reactiv\u0103 sau rotativ\u0103 poate returna pentru scurt timp o parte din energia primit\u0103 anterior. Un astfel de flux de retur nu este o surs\u0103 de energie independent\u0103: el provine din energia livrat\u0103 anterior aceleia&#537;i sarcini.<\/p>\n<\/div>\n<div class=\"vendor-load-topology__grid\">\n<div>\n<span class=\"vendor-label\">Portul de utilizator VENDOR.Max<\/span>\n<p>O singur\u0103 conexiune c\u0103tre sarcina de test.<\/p>\n<\/div>\n<div>\n<span class=\"vendor-label\">Sarcina de test<\/span>\n<p>F\u0103r\u0103 conexiune la re&#539;ea. F\u0103r\u0103 baterie extern\u0103. F\u0103r\u0103 generator extern.<\/p>\n<\/div>\n<div>\n<span class=\"vendor-label\">Retur reactiv<\/span>\n<p>Dac\u0103 exist\u0103, nu este o surs\u0103 independent\u0103.<\/p>\n<\/div>\n<\/div>\n\n<h3>3. Calea de ie&#537;ire &#537;i limita portului de utilizator<\/h3>\n<div class=\"vendor-copy\">\n<p>Prototipul istoric a folosit o cale de ie&#537;ire CA de tip casnic. Ie&#537;irea de utilizator a fost realizat\u0103 ca o interfa&#539;\u0103 protejat\u0103 de 220 V \/ 16 A. Acest lucru se referea la portul de ie&#537;ire &#537;i la implementarea lui electric\u0103, nu la clasa intern\u0103 a instala&#539;iei.<\/p>\n<p>La aceste valori nominale, interfa&#539;a corespunde unei sc\u0103ri de putere aparent\u0103 de 3,52 kVA.<\/p>\n<\/div>\n<div class=\"vendor-callout\">\n<p>16 A este curentul nominal al interfe&#539;ei protejate, nu un prag instantaneu ferm de declan&#537;are. Comportamentul protec&#539;iei depinde de caracteristicile aparatului de protec&#539;ie concret &#537;i de condi&#539;iile sale de func&#539;ionare.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Livrarea a 5 kW ca putere nominal\u0103 printr-o astfel de interfa&#539;\u0103 casnic\u0103 nu a f\u0103cut parte din proiectare.<\/p>\n<\/div>\n<div class=\"vendor-claim\">\n<p>5 kW descria clasa de dezvoltare a prototipului istoric. 220 V \/ 16 A descria implementarea CA casnic\u0103 specific\u0103 a portului s\u0103u de utilizator. Acestea sunt caracteristici diferite.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Reglajul sarcinii electronice la aproximativ 4,0 kW a fost ales ca o condi&#539;ie de lung\u0103 durat\u0103 deliberat solicitant\u0103 pentru aceast\u0103 implementare CA anume, \u00een timp ce sarcini mai mari, apropiate de clasa de dezvoltare de 5 kW, au fost folosite numai \u00een \u00eencerc\u0103ri de v\u00e2rf separate, de scurt\u0103 durat\u0103. Rularea continu\u0103 a examinat astfel at\u00e2t men&#539;inerea pe termen lung a regimului de func&#539;ionare, c\u00e2t &#537;i comportamentul invertorului &#537;i al protec&#539;iei de ie&#537;ire de 16 A sub sarcin\u0103 sus&#539;inut\u0103.<\/p>\n<p>Configura&#539;ia istoric\u0103 de \u00eencercare este consemnat\u0103 ca 220 V \/ 16 A. Aceasta descrie conven&#539;ia nominal\u0103 &#537;i interfa&#539;a folosite \u00een acel loc de \u00eencercare; nu este o afirma&#539;ie c\u0103 tensiunea instantanee la port a r\u0103mas exact 220 V pe toat\u0103 durata func&#539;ion\u0103rii.<\/p>\n<p>Nucleul fizic, implementarea concret\u0103 a componentelor &#537;i interfa&#539;a de utilizator sunt trei niveluri diferite de descriere, iar o caracteristic\u0103 a unuia nu este o caracteristic\u0103 a altuia.<\/p>\n<\/div>\n\n<h3>4. Verificare \u00eencruci&#537;at\u0103 calorimetric\u0103 a sarcinii<\/h3>\n<div class=\"vendor-callout\">\n<p>Observa&#539;iile electrice nu au fost singura modalitate de evaluare a r\u0103spunsului sarcinii. O serie separat\u0103 a folosit calorimetria cu ap\u0103: cantitatea de ap\u0103, cre&#537;terea de temperatur\u0103 &#537;i timpul scurs au fost m\u0103surate direct.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Valorile sunt prezentate \u00een sec&#539;iunea de rezultate.<\/p>\n<\/div>\n\n<h3>5. Monitorizarea st\u0103rii de func&#539;ionare<\/h3>\n<div class=\"vendor-callout\">\n<p>Pe parcursul programului de testare, starea de func&#539;ionare a fost monitorizat\u0103 instrumental \u00een mai multe planuri de m\u0103surare.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Observa&#539;iile din planuri diferite apar&#539;in unor m\u0103rimi fizice diferite, unor ansambluri diferite de sarcini electrice &#537;i unor clase temporale diferite. Punctele-cheie ale st\u0103rii de func&#539;ionare sunt \u00eenregistrate \u00een sec&#539;iunea de rezultate, fiecare cu clasa de m\u0103rime c\u0103reia \u00eei apar&#539;ine. Interpretarea lor &#537;i harta cre&#537;terilor locale apar&#539;in paginii <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/unde-este-plusul\/\">Unde este plusul<\/a>.<\/p>\n<\/div>\n\n<h3>6. Screening electromagnetic intern<\/h3>\n<div class=\"vendor-callout\">\n<p>Programul de testare a inclus observa&#539;ii interne ale mediului electromagnetic, printre care monitorizarea c\u00e2mpului de \u00eenalt\u0103 frecven&#539;\u0103 radiat cu o anten\u0103 de m\u0103surare HyperLOG 7040 &#537;i m\u0103sur\u0103tori punctuale de c\u00e2mp.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Acesta este un screening ingineresc, nu un test de certificare pentru compatibilitate electromagnetic\u0103. Valorile numerice nu sunt publicate: citirile punctuale individuale nu sunt folosite pentru a revendica conformitatea cu standardele.<\/p>\n<\/div>\n\n<h3>Instrumente<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Consemnate \u00een programul de testare. Un instrument intr\u0103 \u00een aceast\u0103 \u00eenregistrare numai atunci c\u00e2nd o urm\u0103 primar\u0103 de test \u00eel confirm\u0103 \u2014 un jurnal, o fotografie, o \u00eenregistrare video sau metoda documentat\u0103 a experimentului concret.<\/caption>\n<thead><tr><th>Echipament<\/th><th>Rol<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Anten\u0103 de m\u0103surare HyperLOG 7040<\/td><td>Observarea c\u00e2mpului de \u00eenalt\u0103 frecven&#539;\u0103 radiat<\/td><\/tr>\n<tr><td>Dozimetru SOEKS Quantum<\/td><td>Verificare punctual\u0103 a mediului<\/td><\/tr>\n<tr><td>Aparat de m\u0103surare a c\u00e2mpului electromagnetic MEGEON<\/td><td>Verificare punctual\u0103 a mediului<\/td><\/tr>\n<tr><td>Sarcin\u0103 electronic\u0103 ITECH IT8626<\/td><td>\u00cenc\u0103rcare controlat\u0103 de lung\u0103 durat\u0103 pentru rularea de 532 de ore<\/td><\/tr>\n<tr><td>C\u00e2ntar<\/td><td>Masa prototipului complet<\/td><\/tr>\n<tr><td>Vas gradat, termometru, cronometru<\/td><td>Calorimetrie<\/td><\/tr>\n<tr><td>\u00cenc\u0103lzitor rezistiv, 2,4 kW; sarcin\u0103 inductiv\u0103 800 W<\/td><td>Aparate de sarcin\u0103 reale<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec vendor-sec--mute\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 3<\/span><h2 id=\"programme\">Programul de testare<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>&#536;apte \u00eenregistr\u0103ri. Fiecare r\u0103spunde unei \u00eentreb\u0103ri diferite.<\/p><\/div>\n<\/div>\n\n<div class=\"vendor-steps\">\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">01<\/div>\n<h3>Rulare continu\u0103 de anduran&#539;\u0103<\/h3>\n<div class=\"vendor-step__body\">\n<p>Revizia A \u00b7 532 h \u00b7 sarcin\u0103 electronic\u0103 reglat\u0103 la aproximativ 4,0 kW &#537;i men&#539;inut\u0103 conectat\u0103 continuu. Men&#539;inerea pe termen lung a regimului de func&#539;ionare &#537;i comportamentul c\u0103ii de ie&#537;ire sub aceast\u0103 condi&#539;ie de sarcin\u0103.<\/p>\n<div class=\"vendor-step__no\">Nu stabile&#537;te prin sine puterea activ\u0103 la portul de utilizator verificat\u0103 independent.<\/div>\n<\/div>\n<\/div>\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">02<\/div>\n<h3>Sesiuni inginere&#537;ti cumulate<\/h3>\n<div class=\"vendor-step__body\">\n<p>Toate configura&#539;iile \u00b7 1000+ h. Porniri &#537;i opriri repetate, niveluri de sarcin\u0103 variate &#537;i de v\u00e2rf, deconect\u0103ri de protec&#539;ie, sesiuni instrumentale de lucru.<\/p>\n<div class=\"vendor-step__no\">Nu descrie o versiune repetat\u0103 a rul\u0103rii continue.<\/div>\n<\/div>\n<\/div>\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">03<\/div>\n<h3>Calorimetria sarcinii<\/h3>\n<div class=\"vendor-step__body\">\n<p>Revizia A \u00b7 cinci repet\u0103ri. Rezultat de \u00eenc\u0103lzire a apei ob&#539;inut printr-o metod\u0103 care nu necesit\u0103 wattmetrie de \u00eenalt\u0103 frecven&#539;\u0103.<\/p>\n<div class=\"vendor-step__no\">Nu stabile&#537;te puterea electric\u0103 total\u0103 absorbit\u0103 de \u00eenc\u0103lzitor.<\/div>\n<\/div>\n<\/div>\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">04<\/div>\n<h3>Sarcin\u0103 dinamic\u0103 combinat\u0103<\/h3>\n<div class=\"vendor-step__body\">\n<p>Revizia B \u00b7 20 de minute. Comportament cu o component\u0103 inductiv\u0103 &#537;i v\u00e2rfuri repetate de pornire.<\/p>\n<div class=\"vendor-step__no\">Nu produce un rezultat energetic cantitativ \u00een aceast\u0103 configura&#539;ie.<\/div>\n<\/div>\n<\/div>\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">05<\/div>\n<h3>Testare p\u00e2n\u0103 la distrugere<\/h3>\n<div class=\"vendor-step__body\">\n<p>Asambl\u0103ri timpurii. Solicitarea deliberat\u0103 a c\u0103ii de putere p\u00e2n\u0103 la defectare pentru a localiza elementul limitativ.<\/p>\n<div class=\"vendor-step__no\">Nu descrie configura&#539;ia folosit\u0103 \u00een rularea continu\u0103.<\/div>\n<\/div>\n<\/div>\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">06<\/div>\n<h3>Demonstra&#539;ie de func&#539;ionare filmat\u0103 sub sarcin\u0103<\/h3>\n<div class=\"vendor-step__body\">\n<p>Revizia B \u00b7 \u00eenregistrare video. Func&#539;ionare cu aparate casnice CA reale.<\/p>\n<div class=\"vendor-step__no\">Nu stabile&#537;te energia transferat\u0103 c\u0103tre aparate.<\/div>\n<\/div>\n<\/div>\n<div class=\"vendor-step\">\n<div class=\"vendor-step__n\">07<\/div>\n<h3>Demonstra&#539;ii \u00een afara laboratorului<\/h3>\n<div class=\"vendor-step__body\">\n<p>Revizia A &#537;i Revizia B \u00b7 mai multe loca&#539;ii \u00een afara laboratorului. Porniri repetate &#537;i func&#539;ionare sub sarcin\u0103 \u00een ambele configura&#539;ii de pornire.<\/p>\n<div class=\"vendor-step__no\">Nu constituie o calificare formal\u0103 de mediu.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 4<\/span><h2 id=\"results\">Rezultate<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>Programul de testare a folosit mai multe forme independente de \u00eenc\u0103rcare &#537;i observare. Ele r\u0103spund unor \u00eentreb\u0103ri diferite &#537;i nu sunt combinate \u00eentr-un singur bilan&#539; energetic calculat. Rularea continu\u0103 de anduran&#539;\u0103 a folosit o sarcin\u0103 electronic\u0103 la aproximativ nivelul de 4,0 kW; \u00eencerc\u0103ri calorimetrice separate au stabilit un rezultat termic pe un aparat rezistiv; sesiunile dinamice &#537;i de v\u00e2rf au testat comportamentul tranzitoriu; demonstra&#539;iile \u00een afara laboratorului au testat repetabilitatea secven&#539;ei observabile de func&#539;ionare.<\/p><\/div>\n<\/div>\n\n<h3>Rularea continu\u0103 de 532 de ore<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Revizia A \u00b7 configura&#539;ie de laborator \u00b7 \u00eenregistrare intern\u0103.<\/caption>\n<thead><tr><th>Parametru<\/th><th>\u00cenregistrare<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Interval continuu<\/td><td data-num>532 h<\/td><\/tr>\n<tr><td>Configura&#539;ie<\/td><td>Revizia A<\/td><\/tr>\n<tr><td>Condi&#539;ia de sarcin\u0103<\/td><td>Sarcin\u0103 electronic\u0103, aproximativ 4,0 kW, conectat\u0103 continuu<\/td><\/tr>\n<tr><td>Pornire<\/td><td>9 V timp de aproximativ 10 s, apoi sursa de pornire deconectat\u0103 fizic<\/td><\/tr>\n<tr><td>\u00centreruperea regimului de func&#539;ionare<\/td><td>Niciuna<\/td><\/tr>\n<tr><td>Defectare hardware<\/td><td>Niciuna<\/td><\/tr>\n<tr><td>Deconectarea portului de utilizator de protec&#539;ia de ie&#537;ire de 16 A<\/td><td>Ne\u00eenregistrat\u0103 pe parcursul intervalului<\/td><\/tr>\n<tr><td>\u00cencheiere<\/td><td>Controlat\u0103, prin decizia operatorilor<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Configura&#539;ia de sarcin\u0103 a r\u0103mas conectat\u0103 constant. \u00cen rulare nu au existat regimuri de v\u00e2rf.<\/p>\n<\/div>\n\n<h3>Timp de func&#539;ionare \u00eenregistrat<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Citiri afi&#537;ate pe ecranul prototipului.<\/caption>\n<thead><tr><th>Citire<\/th><th>Semnifica&#539;ie \u00een \u00eenregistrarea testului<\/th><\/tr><\/thead>\n<tbody>\n<tr><td data-num>532 h 23 min 11 s<\/td><td>Citire asociat\u0103 rul\u0103rii continue \u00een \u00eenregistrarea testului<\/td><\/tr>\n<tr><td data-num>1000 h 00 min 06 s<\/td><td>Timp total de func&#539;ionare, conform etichetei interfe&#539;ei<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<figure class=\"vendor-fig\">\n<img src=\"\/wp-content\/uploads\/2026\/09\/vendor-max-runtime-counter-532-hours-1000-hours.jpg\" alt=\"Contorul de func&#539;ionare al prototipului VENDOR.Max afi&#537;\u00e2nd 532 h 23 min 11 s &#537;i timpul total de func&#539;ionare de 1000 h\" width=\"1156\" height=\"790\" loading=\"lazy\" decoding=\"async\">\n<figcaption>Contorul de func&#539;ionare \u00eencorporat al prototipului istoric VENDOR.Max. Ecranul afi&#537;eaz\u0103 532 h 23 min 11 s \u00een primul c\u00e2mp de timp &#537;i 1000 h 00 min 06 s \u00een c\u00e2mpul Total operating time. \u00cen \u00eenregistrarea testului, prima citire este asociat\u0103 cu rularea continu\u0103 de 532 de ore. Aceasta este o \u00eenregistrare intern\u0103 a prototipului, nu o \u00eenregistrare metrologic\u0103 independent\u0103 a timpului.<\/figcaption>\n<\/figure>\n<div class=\"vendor-note\">\n<p>Valorile 532 h &#537;i 1000+ h folosite pe aceast\u0103 pagin\u0103 sunt rotunjiri ale acestor citiri.<\/p>\n<\/div>\n\n<h3>Puncte-cheie \u00eenregistrate ale st\u0103rii de func&#539;ionare<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Revizia A \u00b7 \u00eenregistrare intern\u0103. Fiecare valoare poart\u0103 clasa de m\u0103rime c\u0103reia \u00eei apar&#539;ine.<\/caption>\n<thead><tr><th>Punct<\/th><th data-num>Valoare<\/th><th>Pa&#537;aportul m\u0103rimii<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Pornire<\/td><td data-num>9 V, aproximativ 10 s<\/td><td>Valoare de eveniment; sursa de pornire este apoi deconectat\u0103 fizic<\/td><\/tr>\n<tr><td>Intrarea p\u0103r&#539;ii rezonante<\/td><td data-num>24 V, 24 A<\/td><td>Valori interne medii raportate separat \u00een acest punct de m\u0103surare; nu sunt publicate ca m\u0103surare sincron\u0103 a puterii active la acela&#537;i port &#537;i nu sunt o putere de intrare Frame 0<\/td><\/tr>\n<tr><td>Partea rezonant\u0103<\/td><td data-num>p\u00e2n\u0103 la 30 kV, p\u00e2n\u0103 la 150 A<\/td><td>Valori de amplitudine ale st\u0103rii rezonante; nu sunt o m\u0103surare sincron\u0103 a puterii active, iar produsul lor numeric nu este puterea de utilizator<\/td><\/tr>\n<tr><td>Condensatorul dup\u0103 punte<\/td><td data-num>450 V<\/td><td>Nivel de tensiune continu\u0103<\/td><\/tr>\n<tr><td>Sarcina de utilizator<\/td><td data-num>aproximativ 4,0 kW<\/td><td>Condi&#539;ie de sarcin\u0103 electronic\u0103 a acestei rul\u0103ri; nu este o valoare nominal\u0103 de produs &#537;i nu este dedus\u0103 din valorile nominale 220 V \/ 16 A ale interfe&#539;ei<\/td><\/tr>\n<tr><td>Durat\u0103<\/td><td data-num>532 h continuu; peste 1000 h cumulat<\/td><td>Contorul de func&#539;ionare al prototipului<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"vendor-callout\">\n<p>Aceste valori apar&#539;in unor frontiere diferite, unor ansambluri diferite de sarcini electrice &#537;i unor clase temporale diferite. Ele nu se \u00eenmul&#539;esc \u00eentre ele, nu se \u00eempart una la alta &#537;i nu formeaz\u0103 un rezultat energetic de ansamblu. Tensiunile &#537;i curen&#539;ii interni descriu circula&#539;ia, nu puterea activ\u0103 la portul de utilizator.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Rularea de 532 de ore a fost efectuat\u0103 cu o sarcin\u0103 electronic\u0103 reglat\u0103 la aproximativ 4,0 kW. Durata nu se \u00eenmul&#539;e&#537;te pe aceast\u0103 pagin\u0103 cu acel nivel de sarcin\u0103 pentru a deduce energia electric\u0103 livrat\u0103: valoarea este publicat\u0103 drept condi&#539;ia de sarcin\u0103 documentat\u0103 a \u00eencerc\u0103rii, nu drept o putere activ\u0103 continu\u0103 m\u0103surat\u0103 la portul de utilizator.<\/p>\n<p>Frecven&#539;ele de regim &#537;i de comand\u0103, duratele ferestrelor &#537;i ale pachetelor, num\u0103rul de impulsuri, factorii de calitate, coeficien&#539;ii de cuplaj, rapoartele dintre puncte &#537;i reparti&#539;ia magistralei nu sunt publicate.<\/p>\n<\/div>\n\n<h3>Calorimetrie<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Revizia A \u00b7 sursa de pornire deconectat\u0103 \u00b7 cinci repet\u0103ri.<\/caption>\n<thead><tr><th>Parametru<\/th><th data-num>Valoare<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Sarcin\u0103<\/td><td>\u00cenc\u0103lzitor rezistiv, putere nominal\u0103 indicat\u0103 pe pl\u0103cu&#539;\u0103: 2,4 kW<\/td><\/tr>\n<tr><td>Cantitate de ap\u0103<\/td><td data-num>1,0 L<\/td><\/tr>\n<tr><td>Temperatur\u0103<\/td><td data-num>20 p\u00e2n\u0103 la 100 \u00b0C<\/td><\/tr>\n<tr><td>Timp scurs<\/td><td data-num>240 s<\/td><\/tr>\n<tr><td>Repet\u0103ri<\/td><td data-num>5<\/td><\/tr>\n<tr><td>Energie de \u00eenc\u0103lzire a apei pe rulare<\/td><td data-num>334,9 kJ \u00b7 calculat\u0103 din m\u0103rimi m\u0103surate<\/td><\/tr>\n<tr><td>Total pe cinci repet\u0103ri<\/td><td data-num>1,67 MJ \u00b7 calculat\u0103<\/td><\/tr>\n<tr><td>Putere termic\u0103 medie de \u00eenc\u0103lzire a apei<\/td><td data-num>1,40 kW \u00b7 calculat\u0103<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Pentru calculul energiei, 1,0 L de ap\u0103 este considerat aproximativ egal cu 1,0 kg.<\/p>\n<p>Calculul folose&#537;te cantitatea de ap\u0103, cre&#537;terea de temperatur\u0103, timpul scurs &#537;i valoarea standard a c\u0103ldurii specifice a apei. El nu folose&#537;te faza semnalului electric, valorile eficace, factorul de umplere sau factorul de putere.<\/p>\n<p>Valoarea de 1,40 kW este un rezultat termic raportat exclusiv la ap\u0103. \u00cenc\u0103lzirea vasului, transferul de c\u0103ldur\u0103 c\u0103tre mediu &#537;i energia de evaporare nu sunt incluse \u00een calcul. Prin urmare, ea nu este o estimare a puterii electrice totale a \u00eenc\u0103lzitorului.<\/p>\n<\/div>\n\n<h3>Sarcin\u0103 combinat\u0103<\/h3>\n<div class=\"vendor-copy\">\n<p>Regimul de func&#539;ionare a r\u0103mas stabil timp de 20 de minute sub sarcini combinate rezistive &#537;i inductive cu v\u00e2rfuri repetate. Nu a avut loc nicio \u00eentrerupere a regimului.<\/p>\n<\/div>\n\n<h3>Peste 1000 de ore nu reprezint\u0103 un singur regim de func&#539;ionare<\/h3>\n<div class=\"vendor-claim\">\n<p>532 de ore reprezint\u0103 o rulare continu\u0103 de anduran&#539;\u0103. 1000+ ore reprezint\u0103 func&#539;ionarea cumulat\u0103 \u00een sesiunile inginere&#537;ti \u00eenregistrate.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Aceste sesiuni includ porniri &#537;i opriri repetate, niveluri de sarcin\u0103 variate &#537;i de v\u00e2rf, sarcini combinate, deconect\u0103ri de protec&#539;ie &#537;i observa&#539;ii instrumentale de lucru.<\/p>\n<p>Demonstra&#539;ia filmat\u0103 de func&#539;ionare &#537;i demonstra&#539;iile \u00een afara laboratorului formeaz\u0103 un ansamblu separat &#537;i mai larg de dovezi. Ele nu sunt contabilizate separat \u00een valoarea de 1000+ ore de pe aceast\u0103 pagin\u0103.<\/p>\n<\/div>\n\n<h3>Declan&#537;area protec&#539;iei &#537;i defectarea sistemului sunt evenimente diferite<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Termeni folosi&#539;i consecvent \u00een aceast\u0103 \u00eenregistrare.<\/caption>\n<thead><tr><th>Termen<\/th><th>Semnifica&#539;ie<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Declan&#537;are de protec&#539;ie<\/td><td>Deconectarea prev\u0103zut\u0103 a portului de utilizator la atingerea unei condi&#539;ii de protec&#539;ie<\/td><\/tr>\n<tr><td>Defectare de sistem<\/td><td>Pierderea neprev\u0103zut\u0103 a st\u0103rii de func&#539;ionare sau o defectare hardware<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Declan&#537;\u0103ri ale protec&#539;iei de ie&#537;ire au avut loc \u00een testele de v\u00e2rf din alte sesiuni &#537;i nu au fost tratate ca defect\u0103ri ale instala&#539;iei. \u00cen rularea de 532 de ore portul de utilizator nu a fost deconectat de protec&#539;ia de ie&#537;ire.<\/p>\n<p>Sesiuni de v\u00e2rf separate au atins niveluri de sarcin\u0103 apropiate de clasa de dezvoltare de 5 kW. Func&#539;ionarea de scurt\u0103 durat\u0103 la asemenea niveluri nu a provocat invariabil o declan&#537;are imediat\u0103 a protec&#539;iei; declan&#537;\u0103ri de protec&#539;ie au fost de asemenea \u00eenregistrate \u00een alte condi&#539;ii de \u00eencercare de v\u00e2rf. Aceste sesiuni au fost separate de rularea continu\u0103 de 532 de ore.<\/p>\n<\/div>\n\n<h3>Demonstra&#539;ie filmat\u0103 de func&#539;ionare sub sarcin\u0103<\/h3>\n<div class=\"vendor-copy\">\n<p>\u00cenregistrarea arat\u0103 secven&#539;a: pornire, stabilirea regimului, conectarea sarcinilor casnice, func&#539;ionare, oprire.<\/p>\n<\/div>\n<div class=\"vendor-callout\">\n<p>\u00cenregistrarea arat\u0103 func&#539;ionarea cu o sarcin\u0103 rezistiv\u0103 cu putere nominal\u0103 indicat\u0103 pe pl\u0103cu&#539;\u0103 de 2,4 kW &#537;i o sarcin\u0103 inductiv\u0103 cu putere nominal\u0103 indicat\u0103 pe pl\u0103cu&#539;\u0103 de 800 W. Valorile nominale indicate pe pl\u0103cu&#539;ele aparatelor nu reprezint\u0103 energia transferat\u0103 m\u0103surat\u0103.<\/p>\n<\/div>\n\n<h3>Demonstra&#539;ii \u00een afara laboratorului<\/h3>\n<div class=\"vendor-copy\">\n<p>Prototipul a fost pornit &#537;i demonstrat \u00een mod repetat \u00een afara laboratorului, \u00een ambele configura&#539;ii.<\/p>\n<p><strong>Revizia A.<\/strong> O baterie extern\u0103 a fost conectat\u0103 la portul de pornire pentru start. Dup\u0103 stabilirea regimului \u2014 dup\u0103 aproximativ 10\u201315 secunde \u2014 bateria a fost deconectat\u0103 fizic de la portul de pornire. Instala&#539;ia a func&#539;ionat apoi \u00een regim de demonstra&#539;ie cu o sarcin\u0103 conectat\u0103.<\/p>\n<p><strong>Revizia B.<\/strong> Pornirea a fost realizat\u0103 de sistemul intern. \u00cen timpul demonstra&#539;iilor \u00een afara laboratorului instala&#539;ia a fost oprit\u0103 &#537;i repornit\u0103 \u00een mod repetat de la \u00eentrerup\u0103torul principal, dup\u0103 care a urmat aceea&#537;i secven&#539;\u0103 observabil\u0103: pornire, stabilirea regimului, conectarea sarcinii, func&#539;ionare, oprire.<\/p>\n<p>\u00cen loca&#539;ii diferite, secven&#539;a observabil\u0103 de pornire &#537;i func&#539;ionare a fost reprodus\u0103 \u00een mod repetat.<\/p>\n<\/div>\n\n<h3>Frontiera acestei \u00eenregistr\u0103ri<\/h3>\n<div class=\"vendor-callout\">\n<p>Frame 0 este suprafa&#539;a de control de produs &#537;i de \u00eencercare, trasat\u0103 de-a lungul carcasei dispozitivului. Frame 1 este frontiera inginereasc\u0103 de control a nucleului de lucru. Acestea sunt volume de control diferite, str\u0103b\u0103tute de fluxuri diferite, astfel \u00eenc\u00e2t un flux intern al Frame 1 nu poate fi desemnat ca intrare extern\u0103 a Frame 0.<\/p>\n<p>\u00cen configura&#539;ia Revizia A, sursa extern\u0103 de pornire traverseaz\u0103 Frame 0 numai \u00een timpul pornirii &#537;i este apoi deconectat\u0103 fizic. Dup\u0103 aceea nu exist\u0103 un port de alimentare extern continuu prev\u0103zut de arhitectur\u0103. Aceasta este o afirma&#539;ie topologic\u0103, nu o afirma&#539;ie c\u0103 orice canal energetic extern posibil lipse&#537;te: un bilan&#539; complet al Frame 0 impune inventarierea &#537;i m\u0103surarea acestor canale \u00eempreun\u0103 cu modificarea rezervelor interne.<\/p>\n<p>Tensiunile &#537;i curen&#539;ii interni apar&#539;in unor clase temporale diferite &#537;i unor ansambluri diferite de sarcini electrice. \u00cenmul&#539;irea lor aritmetic\u0103 sau compararea lor succesiv\u0103 nu formeaz\u0103 un bilan&#539; energetic de ansamblu pe \u00eentregul traseu. F\u0103r\u0103 o distinc&#539;ie corect\u0103 \u00eentre planuri, clase temporale &#537;i frontiera extern\u0103, valori identice de tensiune &#537;i curent admit interpret\u0103ri fizice diferite.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>De aceea site-ul p\u0103streaz\u0103 separate dou\u0103 limbaje: modelul bazat pe sarcina electric\u0103 este folosit pentru mecanismul local &#537;i organizarea mi&#537;c\u0103rii, iar bilan&#539;ul energetic este folosit pentru contabilizarea cantitativ\u0103 la o frontier\u0103 aleas\u0103 explicit.<\/p>\n<p>Aceast\u0103 pagin\u0103 public\u0103 condi&#539;iile &#537;i rezultatele efectiv observate. Planurile de lucru &#537;i modific\u0103rile locale sunt acoperite de <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/unde-este-plusul\/\">Unde este plusul<\/a>. Regulile de contabilizare cantitativ\u0103 a energiei sunt acoperite de <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/model-energetic\/\">Modelul energetic<\/a>. Bilan&#539;ul complet al Frame 0 \u2014 inventarierea tuturor canalelor care traverseaz\u0103 suprafa&#539;a de control de produs, m\u0103surarea ie&#537;irii de utilizator &#537;i urm\u0103rirea modific\u0103rii rezervelor interne \u2014 apar&#539;ine paginii <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/cadrul-validare-tehnologica\/\">Validare tehnologic\u0103<\/a>.<\/p>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec vendor-sec--tint\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 5<\/span><h2 id=\"timeline\">Cum s-a desf\u0103&#537;urat rularea de 532 de ore<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>Secven&#539;a cauzal\u0103 a rul\u0103rii, de la starea f\u0103r\u0103 tensiune p\u00e2n\u0103 la oprirea controlat\u0103.<\/p><\/div>\n<\/div>\n\n<dl class=\"vendor-timeline\">\n<div><dt>T0<\/dt><dd>Instala&#539;ia f\u0103r\u0103 tensiune.<\/dd><\/div>\n<div><dt>T1<\/dt><dd>Sursa extern\u0103 de pornire conectat\u0103: 9 V timp de aproximativ 10 s.<\/dd><\/div>\n<div><dt>T2<\/dt><dd>Regimul de func&#539;ionare stabilit.<\/dd><\/div>\n<div><dt>T3<\/dt><dd>Sursa extern\u0103 de pornire deconectat\u0103 fizic.<\/dd><\/div>\n<div><dt>T4<\/dt><dd>Regimul men&#539;inut.<\/dd><\/div>\n<div><dt>T5<\/dt><dd>Sarcin\u0103 electronic\u0103 reglat\u0103 la aproximativ 4,0 kW, conectat\u0103.<\/dd><\/div>\n<div><dt>T6<\/dt><dd>Func&#539;ionare continu\u0103 cu aceast\u0103 condi&#539;ie de sarcin\u0103 electronic\u0103 \u2014 532 de ore.<\/dd><\/div>\n<div><dt>T7<\/dt><dd>Sarcina deconectat\u0103, rularea \u00eencheiat\u0103 de operatori.<\/dd><\/div>\n<\/dl>\n\n<div class=\"vendor-callout vendor-callout--plain\">\n<p>Rularea a fost \u00eencheiat\u0103 de operatori dup\u0103 532 de ore. Ea a fost oprit\u0103 pentru c\u0103 necesita supraveghere uman\u0103 continu\u0103 a unui prototip experimental \u00een func&#539;iune, nu din cauza unei defect\u0103ri a instala&#539;iei sau a unei declan&#537;\u0103ri de protec&#539;ie.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Regimurile de v\u00e2rf &#537;i declan&#537;\u0103rile de protec&#539;ie nu fac parte din aceast\u0103 rulare &#537;i apar&#539;in altor sesiuni ale programului.<\/p>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 6<\/span><h2 id=\"evidence\">\u00cenregistrare fizic\u0103<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>Ce se poate vedea direct.<\/p><\/div>\n<\/div>\n\n<div class=\"vendor-stack\">\n<figure class=\"vendor-fig\">\n<iframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/qzgqgL9ymU8\" title=\"VENDOR.Max \u2014 demonstra&#539;ie de func&#539;ionare sub sarcin\u0103\" loading=\"lazy\" allow=\"accelerometer; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<figcaption>\u00cenregistrare video a demonstra&#539;iei de func&#539;ionare sub sarcin\u0103. Pornire, stabilirea regimului, conectarea sarcinilor casnice, func&#539;ionare, oprire. Configura&#539;ia Revizia B.<\/figcaption>\n<\/figure>\n\n<figure class=\"vendor-fig\">\n<img src=\"\/wp-content\/uploads\/2026\/09\/vendor-max-prototype-mass-11-3-kg-endurance-test.jpeg\" alt=\"Prototipul istoric VENDOR.Max pe un c\u00e2ntar digital care afi&#537;eaz\u0103 o mas\u0103 de 11,3 kg\" width=\"1024\" height=\"768\" loading=\"lazy\" decoding=\"async\">\n<figcaption>\u00cenregistrare fotografic\u0103 a masei prototipului istoric VENDOR.Max: 11,3 kg. Nu a fost efectuat\u0103 o a doua c\u00e2nt\u0103rire de control dup\u0103 rularea de 532 de ore; fotografia nu este folosit\u0103 pentru a deduce o modificare a masei \u00een timp.<\/figcaption>\n<\/figure>\n\n<figure class=\"vendor-fig\">\n<img src=\"\/wp-content\/uploads\/2026\/09\/vendor-max-soeks-megeon-electromagnetic-radiation-point-check.jpeg\" alt=\"Dozimetru SOEKS Quantum &#537;i aparat de m\u0103surare a c\u00e2mpului electromagnetic MEGEON pe prototipul istoric VENDOR.Max\" width=\"2048\" height=\"1125\" loading=\"lazy\" decoding=\"async\">\n<figcaption>Observa&#539;ii punctuale interne pe prototipul istoric VENDOR.Max. Dozimetrul SOEKS Quantum a fost folosit pentru o verificare punctual\u0103 intern\u0103 a radia&#539;iei; MEGEON pentru o verificare punctual\u0103 intern\u0103 a c\u00e2mpului electromagnetic. Ecranele afi&#537;eaz\u0103 citirile instrumentelor \u00een momentul realiz\u0103rii fotografiei. Acestea nu sunt m\u0103sur\u0103tori de certificare &#537;i nu sunt folosite pentru a revendica conformitatea cu limitele reglementate. Textul \u00een limba rus\u0103 de pe ecranul SOEKS este indica&#539;ia \u00eencorporat\u0103 a instrumentului \u00eensu&#537;i, nu o concluzie a VENDOR.Energy.<\/figcaption>\n<\/figure>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec vendor-sec--mute\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 7<\/span><h2 id=\"output-path\">Implementarea CA testat\u0103 &#537;i defect\u0103rile \u00eenregistrate<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>Ce parte a configura&#539;iei a fost efectiv solicitat\u0103 de rulare &#537;i ce elemente limitative au fost identificate \u00een lucr\u0103rile anterioare.<\/p><\/div>\n<\/div>\n\n<div class=\"vendor-copy\">\n<p>Rularea de 532 de ore s-a referit la o implementare CA istoric\u0103 anume a c\u0103ii de ie&#537;ire: un invertor &#537;i un port de utilizator protejat de 220 V \/ 16 A. \u00cen acest interval invertorul nu s-a defectat, iar protec&#539;ia nu a deconectat portul.<\/p>\n<\/div>\n<div class=\"vendor-callout\">\n<p>Rezultatul se refer\u0103 exclusiv la implementarea CA istoric\u0103 testat\u0103 &#537;i nu se transfer\u0103 automat asupra altor configura&#539;ii de ie&#537;ire. Modul \u00een care este organizat traseul func&#539;ional &#537;i ce configura&#539;ii de ie&#537;ire exist\u0103 sunt prezentate \u00een <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/cum-functioneaza-energie-in-stare-solida\/\">Cum func&#539;ioneaz\u0103<\/a>.<\/p>\n<\/div>\n<div class=\"vendor-copy\">\n<p>Starea de func&#539;ionare a fost dezvoltat\u0103 experimental. Valorile componentelor, condi&#539;iile de comutare &#537;i reglajele de comand\u0103 au fost iterate fa&#539;\u0103 de comportamentul m\u0103surat p\u00e2n\u0103 la ob&#539;inerea unui regim de func&#539;ionare repetabil. Aceast\u0103 \u00eenregistrare descrie ce a f\u0103cut apoi acea implementare fizic\u0103; ea nu reconstruie&#537;te rezultatul dintr-un model energetic de ansamblu prealabil.<\/p>\n<p>\u00cen timpul dezvolt\u0103rii, asambl\u0103rile timpurii au fost aduse deliberat p\u00e2n\u0103 la distrugere. Au fost \u00eenregistrate succesiv trei defect\u0103ri limitative: un ansamblu bobinat, un miez magnetic din ferit\u0103 &#537;i tranzistoarele de putere ale etajului de ie&#537;ire.<\/p>\n<p>Dup\u0103 remedierea fiec\u0103rei defect\u0103ri, elementul urm\u0103tor al c\u0103ii de putere devenea cel limitativ. Aceste rezultate au fost folosite \u00een dezvoltarea ulterioar\u0103 a prototipului.<\/p>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"vendor-sec\">\n<div class=\"vendor-wrap\">\n<div class=\"vendor-head\">\n<div><span class=\"vendor-eyebrow\">Sec&#539;iunea 8<\/span><h2 id=\"meaning\">Ce este \u00eenregistrat &#537;i ce nu este stabilit<\/h2><\/div>\n<div class=\"vendor-head__copy\"><p>\u00cenregistrarea sus&#539;ine afirma&#539;ii despre func&#539;ionarea sistemului. Ea nu \u00eenlocuie&#537;te verificarea independent\u0103.<\/p><\/div>\n<\/div>\n\n<h3>\u00cenregistrat<\/h3>\n<ul class=\"vendor-list--check\">\n<li>prototipul a fost construit &#537;i a func&#539;ionat, iar \u00eenregistrarea acestei func&#539;ion\u0103ri a fost ob&#539;inut\u0103;<\/li>\n<li>regimul de func&#539;ionare a fost men&#539;inut pe un interval lung cu o configura&#539;ie de sarcin\u0103 conectat\u0103 constant &#537;i nu a fost un efect de scurt\u0103 durat\u0103;<\/li>\n<li>pe parcursul rul\u0103rii de 532 de ore nu a fost \u00eenregistrat\u0103 nicio defectare hardware a c\u0103ii de ie&#537;ire CA, iar portul de utilizator nu a fost deconectat de protec&#539;ie;<\/li>\n<li>regimul de func&#539;ionare a fost reprodus \u00een sesiuni repetate;<\/li>\n<li>\u00een afara laboratorului, cicluri repetate de pornire &#537;i func&#539;ionare au fost demonstrate \u00een ambele revizii ale prototipului: \u00een Revizia A bateria extern\u0103 de pornire a fost deconectat\u0103 fizic dup\u0103 stabilirea regimului, iar Revizia B a fost repornit\u0103 de la \u00eentrerup\u0103torul principal folosind sistemul intern de pornire;<\/li>\n<li>\u00een testele de v\u00e2rf din alte sesiuni au fost observate declan&#537;\u0103ri ale protec&#539;iei de ie&#537;ire; \u00een rularea continu\u0103 de 532 de ore cu o configura&#539;ie de sarcin\u0103 conectat\u0103 constant protec&#539;ia nu a deconectat portul;<\/li>\n<li>trei defect\u0103ri limitative au fost stabilite \u00een teste distructive reale;<\/li>\n<li>\u00een seria calorimetric\u0103 au fost m\u0103surate m\u0103rimile ini&#539;iale, iar rezultatul termic de \u00eenc\u0103lzire a apei a fost calculat; metoda nu necesit\u0103 wattmetrie de \u00eenalt\u0103 frecven&#539;\u0103.<\/li>\n<\/ul>\n\n<h3>Nestabilit<\/h3>\n<ul class=\"vendor-list--neg\">\n<li>bilan&#539;ul energetic la frontiera complet\u0103 a dispozitivului;<\/li>\n<li>randamentul de ansamblu al dispozitivului complet;<\/li>\n<li>conformitatea cu cerin&#539;ele de securitate &#537;i de compatibilitate electromagnetic\u0103;<\/li>\n<li>calificarea formal\u0103 de mediu pe domenii definite de temperatur\u0103, umiditate, vibra&#539;ii, praf, grad de protec&#539;ie a carcasei &#537;i mediu electromagnetic;<\/li>\n<li>caracteristicile unei unit\u0103&#539;i de serie.<\/li>\n<\/ul>\n\n<h3>Stratul urm\u0103tor de m\u0103surare<\/h3>\n<div class=\"vendor-tw\">\n<table class=\"vendor-table\">\n<caption>Ce necesit\u0103 fiecare element \u00eenregistrat pentru a deveni un rezultat verificat independent.<\/caption>\n<thead><tr><th>\u00cenregistrat<\/th><th>Stratul urm\u0103tor de m\u0103surare<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Revizia &#537;i exemplarul<\/td><td>Bilan&#539; complet Frame 0 sincron<\/td><\/tr>\n<tr><td>Procedura de pornire; deconectarea sursei de pornire<\/td><td>Bilan&#539; integral al bateriei, acolo unde revizia o con&#539;ine<\/td><\/tr>\n<tr><td>Sarcina conectat\u0103 &#537;i modul de indicare a puterii sale<\/td><td>Flux termic complet<\/td><\/tr>\n<tr><td>Durata func&#539;ion\u0103rii<\/td><td>Flux electromagnetic prin frontier\u0103<\/td><\/tr>\n<tr><td>Men&#539;inerea regimului descris; punctele-cheie ale st\u0103rii de func&#539;ionare<\/td><td>Laborator independent &#537;i buget de incertitudine<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"vendor-scope\">\n<p>Un bilan&#539; energetic nerezolvat nu invalideaz\u0103 un rezultat de func&#539;ionare observat; el limiteaz\u0103 ceea ce se poate deduce din acel rezultat. Observa&#539;ia inginereasc\u0103 nu este o teorie despre sursa de energie.<\/p>\n<p>\u00cenregistrarea a fost realizat\u0103 de companie; bilan&#539;ul la frontiera complet\u0103 nu a fost \u00eenc\u0103 m\u0103surat de un laborator independent \u2014 acesta este stratul urm\u0103tor.<\/p>\n<p>Aceasta este o \u00eenregistrare intern\u0103 de laborator, nu o certificare independent\u0103. Verificarea independent\u0103 este urm\u0103torul strat de dovezi: <a class=\"vendor-link\" href=\"https:\/\/vendor.energy\/ro\/cadrul-validare-tehnologica\/\">Validare tehnologic\u0103<\/a>.<\/p>\n<\/div>\n\n<div class=\"vendor-row\">\n<a class=\"vendor-btn\" href=\"https:\/\/vendor.energy\/ro\/cadrul-validare-tehnologica\/\">Validare tehnologic\u0103<\/a>\n<a class=\"vendor-btn vendor-btn--alt\" href=\"https:\/\/vendor.energy\/ro\/cum-functioneaza-energie-in-stare-solida\/\">Cum func&#539;ioneaz\u0103<\/a>\n<a class=\"vendor-btn vendor-btn--text\" href=\"https:\/\/vendor.energy\/ro\/prima-intrebare-inginereasca-deschisa\/\">Prima \u00eentrebare inginereasc\u0103 deschis\u0103<\/a>\n<\/div>\n<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>\u00cenregistrare intern\u0103 de laborator \u00b7 prototip istoric Test de anduran&#539;\u0103 Ce a fost testat, pentru c\u00e2t timp, sub ce sarcin\u0103, cu ce instrumente &#537;i ce s-a \u00eent\u00e2mplat. Un prototip de laborator VENDOR.Max a finalizat o rulare continu\u0103 de 532 de ore cu o sarcin\u0103 electronic\u0103 reglat\u0103 la aproximativ 4,0 kW &#537;i men&#539;inut\u0103 conectat\u0103 continuu. \u00cen [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-vendor.php","meta":{"footnotes":""},"class_list":["post-29661","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/pages\/29661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/comments?post=29661"}],"version-history":[{"count":6,"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/pages\/29661\/revisions"}],"predecessor-version":[{"id":30170,"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/pages\/29661\/revisions\/30170"}],"wp:attachment":[{"href":"https:\/\/vendor.energy\/ro\/wp-json\/wp\/v2\/media?parent=29661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}